 AWM43000 Series
Mass flow sensor for gases
FEATURES * Ranges 0...1000 sccm1 and 0...6 slpm2 * Actual mass flow sensing * 1...5 V output * Manifold mount/o-ring sealed
SERVICE
To be used with dry gases only The AWM series is NOT designed for liquid flow and will be damaged by liquid flow through the sensor
SPECIFICATIONS
Maximum ratings Supply voltage3 8 to 15 V typ. 10 0.01 V
ELECTRICAL CONNECTION
P1
P2
Power consumption AWM43300V AWM43600V Output load NPN (Sinking) PNP (Sourcing) Temperature limits Operating Storage Mechanical shock
60 mW 75 mW
10 mA 20 mA
123
-25 to 85C -40 to 90C 100 g (5 drops, 6 axes)
Pin 1: Vout Pin 2: +Vs Pin 3: GND
Note: 1 sccm denotes standard cubic centimeters per minute, 1000 sccm = 1 slpm 2 slpm denotes standard liters per minute, which is a flow measurement referenced to standard conditions of 0C, 1 bar, 50% RH. 3 Output voltage is ratiometric to supply voltage
November 2004 / 625
1/4
www.sensortechnics.com
AWM43000 Series
Mass flow sensor for gases
FLOW SENSOR CHARACTERISTICS4
VS = 10 0.01 V, TA = 25C
Part no.
AWM43300V AWM43600V
Flow range (full scale)
1000 sccm1 6 SLPM2
Max. flow ch an g e5
5.0 l/sec 5.0 l/sec
Output voltage @ trim point
5 0.15 V @ 1000 sccm1 5 0.15 V @ 6 SLPM2
PERFORMANCE CHARACTERISTICS
VS = 10 0.01 V, TA = 25C
Characteristics
Zero offset Repeatability and hysteresis (combined) Ratiometricity error3 Temperature effects6 Offset Span -25 to 85 C -25 to 25 C AWM43300V AWM43600V 25 to 85 C AWM43300V AWM43600V Response time Common mode pressure AWM43300V AWM43600V AWM43300V AWM43600V
Min.
0.95
Typ.
1.0
Max.
1.05 0.5 1.0 0.3
Unit
V
% reading
0.025 -5.0 -6.0
V
% reading 6.0 6.0 1.0 3.0 150 p si 25 ms
Notes: 1 sccm denotes standard cubic centimeters per minute, 1000 sccm = 1 slpm 2 SLPM denotes standard liters per minute, which is a flow measurement referenced to standard conditions of 0C, 1 bar, 50% RH. 3 Output voltage is ratiometric to supply voltage 4 A 5 micron filter is recommended for all devices. 5 Maximum allowable rate of flow change to prevent damage. 6 Shift is relative to 25 C.
2/4
November 2004 / 625
www.sensortechnics.com
AWM43000 Series
Mass flow sensor for gases
OUTPUT FLOW VS INTERCHANGEABILITY
VS = 10 0.01 V, TA = 25C
OUTPUT CURVES
GAS CORRECTION FACTORS7
Gas type Helium (He) Hydrogen (H2) Argon (Ar) Nitrogen (N2) Oxygen (O2) Ai r Nitric oxide (NO) Carbon monoxide (CO) Methane (CH4) Ammonia (NH3) Nitrous oxide (N2O) Nitrogen dioxide (NO2) Carbon dioxide (CO2) Correction factor (approx.) 0.58 0.78,9 0.95 1.0 1.0 1.0 1.0 1.0 1.1 1.1 1.35 1.35 1.35
Notes: 7 Gas correction factors are referenced to nitrogen (N2) as calibration gas type. Approximate gas correction factors are provided as guidelines only. Individual gas types may perform differently at temperature extremes and varying flow rates. 8 When sensing Hydrogen (H2) or Helium (He) it may be necessary to power the mass flow sensor using increased supply voltage: Hydrogen typ. 12 V, Helium typ. 15 V 9 Hydrogen (H2) flow measurement requires the use of a special sensor. These devices provide normal operation when sensing hydrogen flow and are designated with an "H" at the end of the order number.
November 2004 / 625
3/4
www.sensortechnics.com
AWM43000 Series
Mass flow sensor for gases
OUTLINE DRAWING
30.5 (1.20) 27.7 (1.09)
14.0 (0.55) 32.2 (1.19)
7.62 (0.30)
321
0.64 (0.025) 34.0 (1.34) 3.0 (0.12) 10.9 8.4 (0.43) (0.33) O 3.0 (O 0.12) O 3.51 (O 0.138) 2.54 (0.10) 7.9 (0.31) 12.7 (0.50)
mass: approx. 11 g
2.5 (0.10)
17.3 (0.68)
4.8 (0.19)
O 6.2 (O 0.24)
P1
123
P2
O 2.0 (O 0.08)
Pin 1: Vout Pin 2: +Vs Pin 3: GND
dimensions in mm (inches)
ORDERING INFORMATION
Flow range 1 0 0 0 sccm 6 S LP M Dry gas AWM43300V AWM43600V Hydrogen gas9 AWM43300VH ---
Note: 9 Hydrogen (H2) flow measurement requires the use of a special sensor. These devices provide normal operation when sensing hydrogen flow and are designated with an "H" at the end of the order number.
Sensortechnics reserves the right to make changes to any products herein. Sensortechnics does not assume any liability arising out of the application or use of any product or circuit described herein, neither does it convey any license under its patent rights nor the rights of others. 4/4 November 2004 / 625
www.sensortechnics.com


▲Up To Search▲   

 
Price & Availability of AWM43600V

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X